High-Rise project >> Assessing the Situation > Current potential >

Refurbishment measures Results      
For each base building Overall            


Moderate climate AS3 countries (base building F)

Headline facts and figures

Broadly representative of Bulgaria and Romania
1.9 million dwellings
40,000 buildings (theoretical)
22% of dwellings in the region
Energy-saving potential in stock: 31%, equivalent to 2.2% of region’s final energy demand or 1.1 MtCO2 emissions

Predominant construction and heating features

Prefabricated concrete panel walls, flat concrete roof and concrete floor, double-glazed, wood frame windows
District heating, allowing installation of TRVs and balancing valves

Cost effectiveness of energy efficiency investment

Energy savings, investment costs and cost of conserved energy

 

U-value before

U-value after

Energy saved [kWh/m2a]

Annual investment cost [€/m2a]

Cost of conserved energy [€cent/kWh]

Simple payback [a]

Walls

1.20

0.30

61.4

33.7%

0.78

1.3

11.0

Roof

2.17

0.24

24.4

13.4%

0.11

0.4

3.8

Floor

1.10

0.45

8.2

4.5%

0.13

1.6

13.7

Windows

2.60

1.80

18.2

10.0%

0.64

3.5

30.6

Package

1.57

0.51

123.7

67.8%

1.66

1.3

11.6

TRVs

54.7

30.0%

0.11

0.2

1.3

All of the above combined

133.4

73.1%

1.77

1.3

11.3

Energy savings, costs of energy and of CO2 mitigation

 

Energy saved [kWh/m2a]

Cost of supplied energy [€cent/kWh]

Cost of conserved energy [€cent/kWh]

Net cost of conserved energy [€cent/kWh]

Cost of CO2 mitigation [€/tCO2]

Net cost of CO2 mitigation [€/tCO2]

Walls

61.4

33.7%

2.0

1.3

-0.7

55

-32

Roof

24.4

13.4%

0.4

-1.6

19

-68

Floor

8.2

4.5%

1.6

-0.4

69

-18

Windows

18.2

10.0%

3.5

1.5

154

67

Package

112.3

61.5%

2.0

1.5

-0.5

65

-23

TRVs

54.7

30.0%

0.2

-1.8

8

-79

All above

133.4

73.1%

1.3

-0.7

58

-29

Issues

Very low fuel prices make investment one of the least cost-effective of all regions.

 