High-Rise project >> Assessing the Situation > Current potential >

Refurbishment measures Results      
For each base building Overall            


Cold climate EU10 countries (base building H)

Headline facts and figures

Broadly representative of Estonia, Latvia, Lithuania and Poland
6.1 million dwellings
125,000 buildings (theoretical)
41% of dwellings in the region
Energy-saving potential in stock: 34%, equivalent to 4.4% of region’s final energy demand or 9.3 MtCO2 emissions

Predominant construction and heating features

Prefabricated concrete panel walls, flat concrete roof and ground floor above an unheated basement, secondary-glazed, plastic frame windows
District heating, allowing installation of TRVs and balancing valves

Cost effectiveness of energy efficiency investment

Energy savings, investment costs and cost of conserved energy

 

U-value before

U-value after

Energy saved [kWh/m2a]

Annual investment cost [€/m2a]

Cost of conserved energy [€cent/kWh]

Simple payback [a]

Walls

1.00

0.28

62.2

30.9%

0.96

1.5

11.8

Roof

0.90

0.30

9.9

4.9%

0.04

0.4

2.9

Floor

0.90

0.45

7.4

3.7%

0.14

1.9

14.9

Windows

3.00

1.80

34.3

17.0%

0.65

1.9

14.5

Package

1.37

0.59

113.9

56.6%

1.79

1.6

12.1

TRVs

60.4

30.0%

0.15

0.3

1.5

All of the above combined

140.2

69.6%

1.95

1.4

10.5

Energy savings, costs of energy and of CO2 mitigation

 

Energy saved [kWh/m2a]

Cost of supplied energy [€cent/kWh]

Cost of conserved energy [€cent/kWh]

Net cost of conserved energy [€cent/kWh]

Cost of CO2 mitigation [€/tCO2]

Net cost of CO2 mitigation [€/tCO2]

Walls

62.2

30.9%

2.3

1.5

-0.7

63

-29

Roof

9.9

4.9%

0.4

-1.9

15

-77

Floor

7.4

3.7%

1.9

-0.3

79

-13

Windows

34.3

17.0%

1.9

-0.4

77

-15

Package

113.9

56.6%

2.3

1.6

-0.7

64

-28

TRVs

60.4

30.0%

0.3

-2.0

10

-82

All above

140.2

69.6%

1.4

-0.9

57

-36

Issues

Highest dwelling proportion, second highest energy saving potential and CO2 reductions.
Fairly homogeneous high-rise stock.
Low cost-effectiveness of investment due to low energy prices.

 